A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the AWT GLOBAL PS1L850 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Cellular Test Set? Shop for Comparable Products on our   new Cellular Test Set page

 
   AWT GLOBAL PS1L850   Description / Specification:    
AWT GLOBAL PS1L850 AMPS/CDMA PIM Analyzer

The AWT-Global PS1L850 AMPS/CDMA PIM analyzer is ideal for component testing in the laboratory and/or during quality control. It offers variable output power from 15 dBm to 44 dBm per channel. Test Modes Include: Diagnostic, Analyzer with Multi-PIM, PIM-over-Time, Sweep Mode, Single Carrier Mode for System Return Loss measurements, Distance to PIM, VSWR, Distance-to-Fault.
Specifications.

System
.
Measurement Method: Reverse (reflected) PIM, 3rd, 5th, 7th, 11th up to 25th order.
Reverse IM: < -129 dBm / -172 dBc.

Transmitter.
Frequencies: 869 ~ 896 MHz.
Frequency increments: 100 kHz.
Frequency accuracy: 2 ppm.
Power (per tone): 15 - 44 dBm adjustable (46 dBm opt).
Power Accuracy: +/- 0.35 dB.
Reverse Power Protection: +43 dBm for 5 sec.

Receiver.
Frequencies: 824 ~ 851MHz.
Measurement Range: -45 dBm to - 132 dBm, -88 dBc to -175 dBc.
Noise Floor: (BW: 300 / 1200 Hz) <-138 / -132 dBm (typical).
Dynamic Range (typical): 96 dB (ref: -70 dBm).
Max Input Power: 0 dBm.
Measurement Accuracy +/- 1.0 dB (typical).

Options.
POPT1: Embedded option for Distance-to-PIM (DTP), Return Loss, VSWR and distance-to-fault.
POPT5: Increases output power, adjustable range from 20 dBm to 46 dBm.
PIMGEN: PIM generator, preset PIM value -80 dBm (+/-10) for quick system tests.



 

Standard Calibration $745.00 *
*This is a Web introductory price for one calibration of the AWT GLOBAL PS1L850. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Communication Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Chirp
A change in the optical frequency caused by direct modulation of the laser. A chirp is a signal in which the frequency increases ('up-chirp') or decreases ('down-chirp') with time. In some sources, the term chirp is used interchangeably with sweep signal.

Nanometer (nm)
A unit of measure used to measure wavelength of light, meaning one one-billionth of a meter

Singlemode Fiber
Singlemode Fiber has a small core, only about 9 microns, and is used for telephony and CATV with laser sources at 1300 and 1550 nm. It can go very long distances at very high speeds. Both multimode and singlemode fiber have an outside diameter of 125 microns - about 5 thousandths of an inch - just slightly larger than a human hair.


Please contact us for your AWT GLOBAL PS1L850 CALIBRATION and/or AWT GLOBAL PS1L850 AMPS/CDMA PIM Analyzer REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: